Model |
GB-S6K-EU |
GB-S8K-EU |
GB-S10K-EU |
GB-S12K-EU |
GB-S15K-EU |
GB-S20K-EU |
|||||||
Battery Input Data |
|||||||||||||
Battery Chemistry |
Li-lon |
||||||||||||
Battery VoltageRange (V) |
150~700 |
||||||||||||
Max. Charging Current(A) |
37 |
||||||||||||
Max. Discharging Current (A) |
37 |
||||||||||||
Numberof battery input |
1 |
||||||||||||
Charging Strategy for Li-IonBttery |
Self-adaption to BMS |
||||||||||||
PV String Input Data |
|||||||||||||
Max.DC Input Power(W) |
7800 |
10400 |
13000 |
15600 |
19500 |
26000 |
|||||||
Max.DC InputVoltage(V) |
1000 |
||||||||||||
Start-up Voltage(V) |
150 |
||||||||||||
MPPT Range(V) |
150-850 |
||||||||||||
Full Load DC VoltageRange (V) |
195-850 |
260-850 |
325-850 |
340-850 |
423-850 |
500-850 |
|||||||
RatedDC InputVoltage(V) |
600 |
||||||||||||
PV Input Current(A) |
20+20 |
26+20 |
26+26 |
||||||||||
Max. PV ISC(A) |
23+23 |
32+23 |
32+32 |
||||||||||
No.of MPP Trackers |
2 |
||||||||||||
No.of Strings per MPP Tracker |
1 |
2+1 |
2 |
||||||||||
AC Output Data |
|||||||||||||
Rated AC Output and UPS Power(W) |
6000 |
8000 |
10000 |
12000 |
15000 |
20000 |
|||||||
Max. AC Output Power(W) |
6600 |
8800 |
11000 |
13200 |
16500 |
22000 |
|||||||
AC Output Rated Current(A) |
9.1 |
12.2 |
15.2 |
18.2 |
22.8 |
30.3 |
|||||||
Max. AC Current(A) |
13 |
18 |
22 |
25 |
30 |
35 |
|||||||
Max. Continuous AC Passthrough(A) |
80 |
||||||||||||
Peak Power (off grid) |
1.5 time of rated power, 10S |
||||||||||||
Generator input/Smart load/AC couple current(A) |
9.1 /80 /9.1 |
12.2 / 80 /12.2 |
15.2 / 80 /15.2 |
18.2 / 80 /18.2 |
22.8 / 80 /22.8 |
30.3 / 80 /30.3 |
|||||||
Power Factor |
0.8 leading to 0.8 lagging |
||||||||||||
Output Frequency and Voltage |
50/60Hz; 3L/N/PE 220/380,230/400Vac |
||||||||||||
Grid Type |
Three Phase |
||||||||||||
DC injection current (mA) |
<0.5%1n |
||||||||||||
Efficiency |
|||||||||||||
Max. Efficiency |
97.60% |
||||||||||||
Euro Efficiency |
97.00% |
||||||||||||
MPPTEfficiency |
99.90% |
||||||||||||
Protection |
|||||||||||||
Integrated |
PV Input Lightning Protection,Anti-islanding Protection,PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection,Surge protection |
||||||||||||
OutputOver VoltageProtection |
DC Type II/AC Type III |
||||||||||||
Certifications and Standards |
|||||||||||||
Grid Regulation |
EN50549, AS4777.2:2015, VDE0126-1-1, IEC61727, VDEN4105-2018, G99 |
||||||||||||
Safety EMC /Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
||||||||||||
GeneralData |
|||||||||||||
Operating Temperature Range (℃) |
-40~60℃, >45℃ derating |
||||||||||||
Cooling |
Smart cooling |
||||||||||||
Communication with BMS |
RS485;CAN |
||||||||||||
Warranty |
5 years |
||||||||||||
Model |
GB-C20K-EU |
||||||||||||
Model |
GB-C20K-EU |
||||||||||||
Charger Module Data |
|||||||||||||
Rate Power (kw) |
20.00% |
||||||||||||
Output Voltage Range (V) |
50~750 |
||||||||||||
Output Current Range (A) |
0~50 |
||||||||||||
Communication Port |
CAN2.0 |
||||||||||||
Charging standard |
CCS2 Type |
||||||||||||
Standards/regulations |
IEC61851-1 |
||||||||||||
Operating Temperature Range (℃) |
40~60 |
||||||||||||
Cooling |
Smart cooling |
||||||||||||
Warranty |
5 years |
||||||||||||
Certification |
EN61851-1/EN61851-23 |
Copyright © Jiangsu Solarman Technology Co.,Ltd. All Rights Reserved - Privacy Policy